Contactor LC1E400F7

Contactor LC1E400F7
Price: $357.69 ×
= 357.69
Manufacturer: Schneider Electric
Model: 004.005.334
Weight: 9.2 kg
In supplier's stock, Delivery time: 08/01/2018
The contactor LC1E400F7 3P 400A 110V 50/60Hz is used to control:
- three-phase motors up to 110 kW at 220...230 V AC 50/60 Hz.
- Resistive circuits up to 500 A (≤ 40 °C) AC AC-1 for power circuit ≤ 440 V.
Control circuit voltage - 110 V AC 50/60 Hz
Main
rangeEasyPact
product nameEasyPact TVS
product or component typeContactor
device short nameLC1E
contactor applicationResistive load
Motor control
utilisation categoryAC-3
AC-1
poles description3P
pole contact composition3 NO
[Ue] rated operational voltage<= 690 V AC 50/60 Hz for power circuit
[Ie] rated operational current400 A (<= 55 °C) AC AC-3 for power circuit <= 440 V
500 A (<= 40 °C) AC AC-1 for power circuit <= 440 V
motor power kW200 kW at 380...400 V
220 kW at 415 V
257 kW at 500 V
280 kW at 660...690 V
110 kW at 220...230 V AC 50/60 Hz
250 kW at 440 V
control circuit typeAC 50/60 Hz
[Uc] control circuit voltage110 V AC 50/60 Hz
height375 mm
width213 mm
depth219 mm
product weight9.1 kg
Complementary
[Uimp] rated impulse withstand voltage8 kV (coil not connected to the power circuit) IEC 60947
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
overvoltage categoryIII
[Ith] conventional free air thermal current500 A <= 40 °C power circuit
Irms rated making capacity4000 A - 440 V AC for power circuit conforming to IEC 60947-4-1
rated breaking capacity3200 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current3600 A at <= 40 °C - 10 s for power circuit
associated fuse rating10 A gG <= 690 V type 1 control circuit IEC 60947-5-1
630 A gG <= 690 V type 1 power circuit
average impedance0.26 mOhm at 50 Hz Ith 500 A for power circuit
power dissipation per pole42 W AC-3
65 W AC-1
control circuit voltage limits0.35...0.5 Uc at <= 55 °C drop-out 50/60 Hz
0.85...1.1 Uc at <= 55 °C operational 50/60 Hz
operating time100...170 ms on opening
40...75 ms on closing
mechanical durability4000000 cycles
operating rate2400 cyc/h at <= 55 °C
inrush power in VA1075 VA at 20 °C (0.9) 50 Hz
1075 VA at 20 °C (0.9) 60 Hz
hold-in power consumption in VA15 VA at 20 °C (0.9) 50 Hz
15 VA at 20 °C (0.9) 60 Hz
heat dissipation14 W for control circuit
minimum switching current5 mA control circuit
minimum switching voltage17 V control circuit
non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
insulation resistance> 10 MOhm control circuit
electrical durability600000 cycles AC-3
250000 cycles AC-1
mounting supportPlate
connections - terminalsPower circuit : cable with lug - 2Ø150 mm
Power circuit : bars - 2 30 x 5 mm
Control circuit : screw clamp terminals - 1 flexible cable(s) 1...4 mm² without cable end
Control circuit : screw clamp terminals - 2 flexible cable(s) 1...4 mm² without cable end
Control circuit : screw clamp terminals - 1 flexible cable(s) 1...4 mm² with cable end
Control circuit : screw clamp terminals - 2 flexible cable(s) 1...2.5 mm² with cable end
Control circuit : screw clamp terminals - 1 solid cable(s) 1...4 mm² without cable end
Control circuit : screw clamp terminals - 2 solid cable(s) 1...4 mm² without cable end
tightening torque1.2 N.m for control circuit
35 N.m for power circuit
Environment
standardsIEC 60947-1
IEC 60947-4-1
IEC 60947-5-1
product certificationsEAC
IP degree of protectionIP2x conforming to IEC 60529
protective treatmentTH IEC 60068 3
pollution degree3
ambient air temperature for operation-5...55 °C
ambient air temperature for storage-60...80 °C
permissible ambient air temperature around the device-20...70 °C at Uc
operating altitude3000 m without derating
fire resistance850 °C IEC 60695-2-1
mechanical robustnessVibrations contactor closed 5 Gn, 5...300 Hz
Vibrations contactor open 1.5 Gn, 5...300 Hz
Shocks contactor closed 15 Gn for 11 ms
Shocks contactor open 6 Gn for 11 ms

EasyPact TVS catalogue (english) [4,409 k]