EasyPact circuit breaker EZC100H1025 25kA/240V 25A

Circuit breaker EZC100H1025
Price: 54.57 ×
= 54.57
Manufacturer: Schneider Electric
Model: 003.002.428
Weight: 349 g      Barcode: 3303430301028
In supplier's stock
Single-pole circuit breaker EZC100H1025 with positive contact indication is suitable for isolation as defined in IEC standard 60947-2.
  • Overload and short-circuit protection
  • Thermal-magnetic trip unit
  • Rated current 25A
  • Breaking capacity Icu at 220...240V 25kA
Main characteristics
Range of productEasyPact
Product or component typeCircuit breaker
Device short nameEasypact EZC100H
Poles description1P
Protected poles description1t
Circuit typeAC
DC
Frequency50/60 Hz
[In] Rated current25 A (40 °C)
[Ui] Rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] Rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] Rated operational voltage125 V DC conforming to IEC 60947-2
415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2
25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] Rated service breaking capacity5 kA at 125 V DC conforming to IEC 60947-2
12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolationconforming to IEC 60947-2
Utilisation categoryCategory A
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Protection typeShort-circuit protection
Overload protection
Pollution degree3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary characteristics
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Upside connectionFront
Downside connectionFront
Mechanical durability8500 cycles
Electrical durabilityCategory A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch25 mm
Local signallingPositive contact indication
Neutral protection settingWithout protection
Earth-leakage protectionWithout
Height130 mm
Width25 mm
Depth60 mm
Environment
StandardsJIS C8201-2-2
EN/IEC 60947-2
EN/IEC 60947-1
GB/T 14048.2
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-35…85 °C
Dimensions
EasyPact Schneider Electric 1-pole circuit breaker dimensions
Tripping curves
EasyPact Schneider Electric 25А circuit breaker tripping curves
EZC100 series circuit breakers model range
Number of poles Rated current, A Schneider Electric catalogue number
Breaking capacity Icu at 220...240V 18kA 25kA
1

15 EZC100N1015 EZC100H1015    
16 EZC100N1016 EZC100H1016    
20 EZC100N1020 EZC100H1020    
25 EZC100N1025 EZC100H1025    
30 EZC100N1030 EZC100H1030    
32 EZC100N1032 EZC100H1032    
40 EZC100N1040 EZC100H1040    
45 EZC100N1045 EZC100H1045    
50 EZC100N1050 EZC100H1050    
60 EZC100N1060 EZC100H1060    
63 EZC100N1063 EZC100H1063    
75 EZC100N1075 EZC100H1075    
80 EZC100N1080 EZC100H1080    
100 EZC100N1100 EZC100H1100    
Breaking capacity Icu at 220...240V 50kA
2

15 EZC100H2015      
16 EZC100H2016      
20 EZC100H2020      
25 EZC100H2025      
30 EZC100H2030      
32 EZC100H2032      
40 EZC100H2040      
45 EZC100H2045      
50 EZC100H2050      
60 EZC100H2060      
63 EZC100H2063      
75 EZC100H2075      
80 EZC100H2080      
100 EZC100H2100      
Breaking capacity Icu at 400...415V 7.5kA 10kA 15kA 30kA
3

15 EZC100B3015 EZC100F3015 EZC100N3015 EZC100H3015
16 EZC100B3016 EZC100F3016 EZC100N3016 EZC100H3016
20 EZC100B3020 EZC100F3020 EZC100N3020 EZC100H3020
25 EZC100B3025 EZC100F3025 EZC100N3025 EZC100H3025
30 EZC100B3030 EZC100F3030 EZC100N3030 EZC100H3030
32 EZC100B3032 EZC100F3032 EZC100N3032 EZC100H3032
40 EZC100B3040 EZC100F3040 EZC100N3040 EZC100H3040
45 EZC100B3045 EZC100F3045 EZC100N3045 EZC100H3045
50 EZC100B3050 EZC100F3050 EZC100N3050 EZC100H3050
60 EZC100B3060 EZC100F3060 EZC100N3060 EZC100H3060
63 EZC100F3063 EZC100N3063 EZC100H3063
75 EZC100F3075 EZC100N3075 EZC100H3075
80 EZC100F3080 EZC100N3080 EZC100H3080
100 EZC100F3100 EZC100N3100 EZC100H3100
Breaking capacity Icu at 400...415V 15kA 30kA
4

15 EZC100N4015 EZC100H4015    
16 EZC100N4016 EZC100H4016    
20 EZC100N4020 EZC100H4020    
25 EZC100N4025 EZC100H4025    
30 EZC100N4030 EZC100H4030    
32 EZC100N4032 EZC100H4032    
40 EZC100N4040 EZC100H4040    
45 EZC100N4045 EZC100H4045    
50 EZC100N4050 EZC100H4050    
60 EZC100N4060 EZC100H4060    
63 EZC100N4063 EZC100H4063    
75 EZC100N4075 EZC100H4075    
80 EZC100N4080 EZC100H4080    
100 EZC100N4100 EZC100H4100    

Circuit breakers EasyPact EZC [19,188 k]
Instructions for accessories circuit breakers EasyPact EZC100 [1,595 k]